Dental Implants Research - Dentistry, Surgery, Tooth Implants

Dental Implants Research Today is a free monthly online journal that collates and summarizes the latest research about Dental Implants, including details on dentistry, surgery, tooth implants.


Dental Implants Research Today

Home

View Latest Issue

Information About Dental Implants

Books on Dental Implants

Advertising in Research Today

View Other Research Today Publications



Load-related implant reaction of mini-implants used for orthodontic anchorage.

Büchter A, Wiechmann D, Koerdt S, Wiesmann HP, Piffko J, Meyer U

Department of Cranio-Maxillofacial Surgery, University of Münster, Münster, Germany. Buchtea@uni-muenster.de

The purpose of this study was to determine the clinical and biomechanical outcome of two different titanium mini-implant systems activated with different load regimens. A total of 200 mini-implants (102 Abso Anchor and 98 Dual Top) were placed in the mandible of eight Göttinger minipigs. Two implants each were immediately loaded in opposite direction by various forces (100, 300 or 500 cN) through tension coils. Additionally, three different distances between the neck of the implant and the bone rim (1, 2 and 3 mm) were used. The different load protocols were chosen to evaluate the load-related implant performance. The load was provided by superelastic tension coils, which are known to develop a virtually constant force. Non-loaded implants were used as a reference. Following an experimental loading period of 22 and 70 days half of the minipigs were sacrificed, and implant containing bone specimens evaluated for clinical performance and implant stability. Implant loosing was found to be statistically dependent on the tip moment (TM) at the bone rim. Clinical implant loosing were only present when load exceeded 900 cN mm. No movement of implants through the bone was found in the experimental groups, for any applied loads. Over the two experimental periods the non-loaded implants of one type of implant had a higher stability than those of the loaded implants. Dual Top implants revealed a slightly higher removal torque compared with Abso Anchor implants. Based on the results of this study, immediate loading of mini-implants can be performed without loss of stability when the load-related biomechanics do not exceed an upper limit of TM at the bone rim.

Published 24 August 2005 in Clin Oral Implants Res, 16(4): 473-9.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Dental Implants Research Today. All Rights Reserved.



Dental Implants Research Today Archive:

Volume 1 (2004)
  Issue 1 (October)
  Issue 2 (November)
  Issue 3 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Dental Implants Books

Osseointegration in Dentistry: An Overview

Osseointegration in Dentistry: An Overview